If your boiler does not operate, please check the Manufacturer’s user instructions. We have detailed some helpful instructions, below (Please note, we do not accept responsibility for the misuse of these instructions). If in doubt, please call the Manufacturer’s help line.
The water pressure gauge must read between 1 bar and 1.5 bar (10Mg-15Mg) when the system is cold. If the pressure is below the .5Bar (5 Mg), top up the pressure.
If your radiators are cold at the top and warm at the bottom, this could indicate air or hydrogen build up in the radiator. Releasing the air or hydrogen from the radiator air vent, should solve the problem, however, if you have a pressurised system, you will have to be more careful.
Releasing air or hydrogen from a radiator that is fitted on a sealed pressurised system, will cause the system pressurise to fall; the system must be depressurised using the guidelines in the paragraph titled “Filling Point”.
If the heating system has a hydrogen build up it is most probably due to corrosion in the system. (Diagram of radiator with air build up).
If your radiators down stairs are cold at the bottom and hot at the top, this could indicate sludge build up in the radiator and your heating system will require a chemical clean with a power flush. (Diagram of radiator with sludge builds up).
These work by control the amount of heat the radiator emits by sensing the air temperature. So therefore setting the thermostatic valve to setting 3 will cause the radiator to cool once it has reached that setting. Remember that the valve is sensing the air temperature so do not expect the temperature of the radiator to remain constant it will fluctuate between on and off as required (diagram of Drayton try).
These units are very reliable, if you do not have any figures on the display, check that the power supply has not been interrupted i.e. accidentally turned off or a fuse has blown. It is important to note that, if a fuse has blown, then it normally indicates a fault occurring on a heating component. If you feel that you want to change the fuse, be aware, that it must be a maximum of 3 amps; fitting a fuse of higher amperage may cause serious damage to any electrical components on the heating system. (Diagram of Drayton programmer).
During heating operation you may experience creaking noises, especially, when the system, initially, starts in the morning. This is caused by the expansion of the heating pipes resting in wooden joists which are amplified at the radiators. These noises are usual and to be expected. There is not a lot that can be done to reduce these noises and you will soon get used to them.
Some boilers require ventilation for combustion purposes and this is provided by air ventilators fitted in the wall, floor or windows. The ventilator must have the following characteristics:
Condencing boilers can, at particular times of their operation cycle, produce visible pluming from the flue turret outside. This pluming is entirely safe and non toxic which is made up mostly of water vapour. Please Click Here to see picture.
If you smell gas: locate your emergency control valve and turn the gas off; open all windows and doors and extinguish any naked flames; and do not operate any electrical switches.
Call the National Gas Emergency Service? on 0800111999 for one of their engineers to attend, this is free service. http://www.nationalgrid.com/uk/Gas/Safety/Emergency
If you have a water leak from a boiler or heating system, don’t worry, you will find that just taking some simple steps will contain the leak until you can contact an engineer;